TMP-S2-FV Radiation Detection & Monitoring for Military Vehicles

DESCRIZIONE

Command & Control Systems
The solution for radiological threat detection.

TMP--S2-FV Systems
tmp-52fv-01.jpg
System Features

  • Extended measurement range from background to full radiac threat levels
  • Rapid response to radiological material
  • Variable alarm threshold
  • Rugged, lightweight, modular design
  • Up to 3 detectors per system
  • Total dose accumulation for mission
  • Excellent reliability for extended deployment
  • Simple user interface and diagnostics
  • Low through life costs

Specification and Type Test

Radiological Performance
Range: 10nGy.h-1 to 100Gy.h-1 ±20%
Energy Response:
60keV to 1MeV; ±35% (predicted)
1MeV to 3MeV ±20%
Polar Response: (137Cs)
- -90° to -75°; ±40%
+75° to +90° ±40%
Power Supply
28V nominal - 15V to 40V dc Bandwidth
Dimensions
Detector - 170w x 55h (mm)
Remote Unit - 77w x 147h x 42d (mm)
Control Unit - 240w x 126h x 62d (mm)
Weights
Detector – 0.75kg
Remote Unit – 0.45kg
Control Unit – 1.57kg
Type Test
Vibration - Def Stan 00-35 Tracked Vehicles
Shock - Def Stan 00-35
Temperature - -40°C to +80°C (operating)
Humidity - 93±2% RH at 55°C
Water Resistance - IP67 (4m depth for detectors); Def Stan 00-35 (for enclosures)
EMC - Def Stan 59-41 Pt3
EMP - Def Stan 59-41 DCS05
TREE - Def Stan 08-4

Options

For use on soft skinned vehicles. The detector colour is produced to customer specification and is available with either a side connector or a flush-mounted configuration with rear connector for inconspicuous mounting.


TMP S2-FV Modular System Approach

tmp-52fv-02.jpgThe nature of the TMP-S2-FV system means that the modules can be linked together in different ways to suit a number of applications.
One detector linked to a control unit and remote display can be used as a basic system, for example on soft skinned vehicles. Two detectors, one mounted on either side of the vehicle linked to a control unit and remote display, provides external radiation level data to the crew and gives a directional capability.
A third detector can be added to the system and either mounted inside the crew compartment to provide radiation exposure levels, or mounted on the front or the rear of the vehicle to provide additional data.
The system provides for the option of a control unit linked to a remote display in vehicles where space is at a premium, or a combined control and display unit for use in vehicles where there is sufficient room.

TMP-AP4C-F
The TMP-AP4C-F is a chemical Warfare Agents and Toxic Industrial material detector for fixed sites.
tmp-52fv-072.jpg
Feature Highlights
  • Simultaneous detection of mixed agents
  • Very short response time and reset time
  • Adapted to harsh environmental conditions
  • Networking with up to 10 detectors
  • No maintenance for one year.
TMP-AP4C-F is a chemical warfare agent detector to be used in a battlefield or urban environment on moving platforms for reconnaissance missions. TMP-AP4C-F detects in real time and simultaneously all category 1 chemical warfare agents and numerous toxic industrial materials.
All nerve agents, blister agents, and blood agents can be detected thus making the TMP-AP4C-F an instrument of safety. TMP-AP4C-F can detect all those agents under vapour, aerosol or liquid form.
TMP-AP4C-F is installed as a fixed alarm system and does not require any other maintenance or human intervention during one year, other than the addition of one litre of water per month.
TMP-AP4C-F has the same capacity of chemical detection and the same specifications as the TMP-AP4C. It is typically installed at the air intake of buildings or critical infrastructures.
Set up procedure, calibration, filter change, purge procedure, and switch off procedure are NOT necessary.
TMP-AP4C-F can be networked with other instruments.
Upon alarm it can trigger the closing of the building ventilation system.

Operating principle

It is based on flame spectrophotometry technology. It operates by in analyzing the light spectrum of a flame of hydrogen. If chemical warfare agents or industrial toxic materials are present in the atmosphere, some specific chemical bonds will emit a characteristic light spectrum that will be recognized by the AP4C optical system.

List of detected chemicals

Tabun GA - Arsine SA
Sarin GB - Diphenylchloroarsine DA
Soman GD - Adamsite DM
Cyclo-sarin GF - Deiphenylcyanoarsine DC
Vx - BZ
VX - CNS
Distilled mustard HD - Bromobenzylcyanide CA
Nitrogen mustard HN-1 - CS
Nitrogen mustard HN-2 - CR
Nitrogen mustard HN-3 - Chloropicrin PS
Phosgene CX - Runcol
Lewisite L - Precursor of OPA
Mustard lewisite mixture HL - Precursor of DF
Phenyldichloarsine PD - EDMP
Ethyldichloarsine ED – Lewisite
Methyldichloarsine MD
Hydrogen cyanide AC
Cyanogen chloride CK

Chemical qualification
Reports available from international independent and recognized laboratories on demand.
Sensitivity in vapors, aerosols, droplets and dust in the air:
  • 10 μg/m3 for all G, V agents
  • 0.5 mg/m3 for H, HD and HL
  • 1.5 mg/m3 for L, SA
  • 10 mg/m3 for HN, HCN
Characteristics
Applications Control of contamination, surveillance of sites
Principle Flame spectrophotometry
Detected gases - Chemical warfare agents (CWA): GA (Tabun), GB (Sarin), GD (Soman), HD (Yperite), VX, Runcol (HT), Cyanhydric acid (HCN), Chlorine cyanogen (AC)
Toxic Industrial materials: Ammonia (NH3), NOx, H2S…
Detection time 2 seconds
Power supply 24 VDC x 3 A max
Size 321 mm x 170 mm x 223 mm (12.63” x 6.69” x 8.77”)
Lifespan One month
Weight 15 kg
Temperatures
-25°C to +50°C (operation)
-32°C to +71°C (storage)

TMP-AP4C-V
The TMP-AP4C-V is a chemical agent detector for fixed or mobile applications. It is used to detect Chemical Warfare Agents and Toxic Industrial Chemicals.
tmp-52fv-08.jpg
Purpose
The TMP-AP4C-V is used in fixed positions (shelters, storage areas) or mobile (reconnaissance vehicles, light vehicles).
The TMP-AP4C-V detects all nerve, all blister and all blood agents.

Main features

  • Fast and remote controlled turn-on
  • Immediate identification and measurements
  • Remote report of information
  • Dynamic filtration of dust
  • Fast response time and fast return-to-zero time.
  • Flameproof.
Operating principle
The TMP-AP4C-V is a flame spectrophotometer. A continuous stream of air is burned into a combustion chamber, which has a constant supply of hydrogen.
A miniaturized spectrophotometer measures the luminous emitting variations of the flame. The electrical signal from the photo sensor is processed in real time by a micro controller board.
Detection
  • Detects simultaneously agents on the four channels.
  • Detects agents in all forms: vapor aerosols - droplets - dust agents and frozen agents.
  • Capability to detect TIC's: PH3, PARATHION on P channel- PCl3, NH3, NOx on HNO channel- SO2, SF6, CS2, H2S, H2S043 on As channel on S channel – AsH
Use specifications
  • Ultra fast response time: 2 seconds at the high sensitivity.
  • Ultra fast return-to-zero after detection even in high concentration.
  • Detects continuously: no need to change filter after positive detection.
  • Starts up within 2 minutes. Restart in 30 seconds. No calibration. Built-in test included.
List of detected chemicals
Tabun GA - Arsine SA
Sarin GB - Diphenylchloroarsine DA
Soman GD - Adamsite DM
Cyclo-sarin GF - Deiphenylcyanoarsine DC
Vx - BZ
VX - CNS
Distilled mustard HD - Bromobenzylcyanide CA
Nitrogen mustard HN-1 - CS
Nitrogen mustard HN-2 - CR
Nitrogen mustard HN-3 - Chloropicrin PS
Phosgene CX - Runcol
Lewisite L - Precursor of OPA
Mustard lewisite mixture HL - Precursor of DF
Phenyldichloarsine PD - EDMP
Ethyldichloarsine ED – Lewisite
Methyldichloarsine MD
Hydrogen cyanide AC
Cyanogen chloride CK

Characteristics
  • Size (LxWxH): 335mm x 170mm x 223mm (13.2" x 6.7" x 8.78")
  • Weight (with 2 hydrogen storage devices): 4 kg
  • Response time: 2 seconds
  • Temperature range
    • in operation: -32°C to +50°C (-25,6° F to + 122° F)
  • Temperature range
    • in storage: -39°C to + 71°C
  • Sensitivity in vapors, aerosols, droplets and dust in the air:
    • 10 f.]g/m 3 for all G, V agents
    • 0.5 mg/m3 for H, HO and HL
    • 1.5 mg/m3 for L, SA
    • 10 mg/m3 for HN, HCN
  • Operational up to 10 000 feet altitude (3 000 meters).
  • Lifespan: 24 h
  • Power supply: 24 V x 3 A max
TMP-MAB
Biological Alarm Monitor

tmp-52fv-10.jpgIt continuously analyses particles in the atmosphere, and searches for specific chemical signatures of bacteria or toxins such as anthrax, plague, Botox, legionella etc., and gives alarm when the concentration in the air of those suspect particles increases. It allows to trigger a bio sampler to determine the pathogenic characteristics of the detected particles.

TMP-MAB immediately detects any evolution regarding to the atmospheric background and gives an alarm as soon as the measured biological characteristics exceed an adjustable threshold.
TMP-MAB works on a continuous basis and in real time.
Response time is some seconds.
It has a very low power consumption (some watts) and a reduced sound level.

TMP-MAB can be used by untrained people and is especially adapted to the harshness of a military use (fast startup, reliability, environmental resistance, continuous running for several days). It has already been selected by several military forces and equips several NBC reconnaissance vehicles, as it is unsensitive to diesel vapors and smokes.
Test reports are available.

Characteristics

  • Size of the box (LxWxH): 300mm x 160mm x 470mm (11.8" x 6.3" x 18.5")
  • Total height: 850mm (33.5")
  • Weight: 14 kg
  • Operating temperature:
  • o -10°C to +50°C (14°F to +122°F)
  • Storage temperature:
  • o -39°C to +71°C (-38.2°F to +160°F)
  • Autonomy: 10 days (refillable hydrogen cylinder included in the appliance)
  • Power supply: 12 - 32 V DCCan be remote controlled
  • Remote data by RS 485 outlet
  • Response time: less than 1 minute.
  • In serial production
  • Field tested / Report available
TMP-AP4C
Hand held, portable monitoring and detection unit used by military, civil defense and environmental agencies.
tmp-52fv-14.jpg
Purpose
The TMP-AP4C is a portable chemical contamination control device used to detect directly chemical agents in the form of vapor, aerosols, dust and with the S4PE in the form of liquid. The TMP-AP4C is particularly suitable for use in rough conditions:
  • Fast turn on
  • continuous measurement
  • Single-handed operation
  • Simplicity of use
  • TMP-AP4C can be used in flamable areas
The TMP-AP4C detects all nerve, all blister and all blood agents.
New features
  • Internal data storage and download
  • ATP45 format messages
Operating principle
The TMP-AP4C is a flame spectrophotometer. A continuous stream of air is burned into a combustion chamber. A miniaturized spectrophotometer analyzes the spectra of the flame light

Detection

Detects simultaneously agents on the four channels.
Detects agents in all forms: vapor aerosols - droplets - dust agents and frozen agents.
Detects persistent agents spread on most surfaces (VX, thicked SOMAN, HD at low temperatures).
Detects agents in water, on the skin (medical use)
Capability to detect TIC's: PH3, PARATHION on P channel- PCl3, NH3, NOx on HNO channel- SO2, SF6, CS2, H2S, H2S04 on S channel – AsH3 on As channel.

Use specifications

  • Ultra fast response time: 2 seconds at the high sensitivity.
  • Ultra fast return-to-zero after detection even in high concentration.
  • Detects continuously: no need to change filter after positive detection.
  • Starts up within 2 minutes. Restart in 30 seconds. No calibration. Built-in test included.
New features
  • Internal data storage and download
  • TMP-ATP45 format messages
List of detected chemicals
Tabun GA - Arsine SA
Sarin GB - Diphenylchloroarsine DA
Soman GD - Adamsite DM
Cyclo-sarin GF - Deiphenylcyanoarsine DC
Vx - BZ
VX - CNS
Distilled mustard HD - Bromobenzylcyanide CA
Nitrogen mustard HN-1 - CS
Nitrogen mustard HN-2 - CR
Nitrogen mustard HN-3 - Chloropicrin PS
Phosgene CX - Runcol
Lewisite L - Precursor of OPA
Mustard lewisite mixture HL - Precursor of DF
Phenyldichloarsine PD - EDMP
Ethyldichloarsine ED
Methyldichloarsine MD
Hydrogen cyanide AC
Cyanogen chloride CK
Maintenance
Storage period: No maintenance required during storage period
Use period: Check up 1 time per year.

Characteristics

  • Size (LxlxW): 385 mm x 100 mm x 138 mm (15.15" x 3.94" x 5.43")
  • Weight - in operation: 2 kg (41/z lbs)
  • Power supply: battery or external supply (12-28 V DC with power block) or rechargeable battery
  • Wireless networking capability.
NOTE: The detector can be transformed into an alarm system by adding a simple accessory (alarm module) in place of the battery drawer. The alarm can be remote controlled on a special display up to 400 meters. Use: Surveillance of offshore airports, projected bases...